System Limit Requirements
 
 Check the definitions in BPXPRMxx. The following guidelines are approximate 
and apply to both the server and the clients.
 Tectia requires an address space size of at least 200 MB (MAXASSIZE). 
 Each concurrent connection typically needs 2 to 3 processes (MAXPROCSYS, 
MAXPROCUSER). The user limit may require adjusting if many concurrent 
connections are run under one user ID.
 For each concurrent connection Tectia requires:
 
-  file descriptors (MAXFILEPROC)
 -  TCP/IP sockets (MAXSOCKET for file system type INET)
 -  AF_UNIX sockets (MAXSOCKET for file system type UDS)
 
 The limits suggested in the z/OS UNIX System Services Planning book are 
typically adequate except maybe for AF_UNIX. Tectia uses 3 to 4 AF_UNIX 
sockets for each concurrent connection.